Hub & Setup

Tech specs

WS90

WS69

Finish

WS90

WS69

Features

  • Piezoelectric rain gauge;
  • Ultrasonic anemometer(start wind speed 0.3m/s);
  • Temperature;
  • Humidity;
  • Solar light intensity and UV index;
  • Waterproof IPX5;
  • Heater and additional power supply;
  • Mechanical rain gauge;
  • Mechanical anemometer (start wind speed 1.5m/s);
  • Temperature;
  • Humidity;
  • Solar light intensity and UV index;

Specifications

MeasurementRangeAccuracyResolution
Wind speed 0m/s to 40m/s <10m/s, ±0.5m/s; ≥10m/s, ±5% 0.1m/s
Wind direction 0° to 359° <2m/s, ±10°; ≥2m/s, ±7° 
Temperature-40°C to 60°C ±0.3°C (± 0.6°F) 0.1°C (± 0.2°F)
Humidity1% to 99% ±3.5% 1%
Light0Klux to 200Klux ±15% 0.1Klux
UVI1 to 15 ±2 1
Rain0 to 9999 TBA0.1mm
MeasurementRangeAccuracyResolution
Wind speed 0m/s to 50m/s ±1 m/s (speed < 10 m/s);
 ± 10% (speed ≥ 10 m/s)
0.1m/s
Wind direction 0° to 359° ± 15° 
Temperature-40°C to 60°C ±0.3°C (± 0.6°F) 0.1°C (± 0.1°F)
Humidity1% to 99% ±3.5% 0.01
Light0Klux to 200Klux ±25% 0.1Klux
UVI1 to15 ±2 1
Rain0 to 9999 ± 10% 0.3 mm (for volume < 1,000 mm);
 1 mm (for volume ≥ 1,000 mm

Transmission between gateway and sensor

  • Transmission distance in open field: 150 m (500 ft.) depend on environment.
  • RF frequency: 433/868/915/920 MHz depending on location
  • Updates on sensor reporting interval: 8.8 seconds
  • Transmission distance in open field: 100 m (330 ft.) depend on environment. 
  • RF frequency: 433/868/915 MHz depending on location
  • Updates on sensor reporting interval: 16 seconds

GW2000

GW1100

Finish

GW2000

WS69

Features

  • OTA upgrade
  • WLAN or LAN Wi-Fi gateway
  • Barometric
  • Indoor temperature
  • Indoor humidity
  • WLAN gateway
  • Barometric
  • Indoor temperature
  • Indoor humidity

Specifications

MeasurementRangeAccuracyResolution
Barometric300 to 1100 hPa (8.85 to 32.5 inHg) ± 5hPa 0.1hPa (0.01 inHg)
Temperature
(Indoor) 
-10°C to 60°C (-14°F to 140°F) ± 0.3°C (± 0.6°F) 0.1°C (0.1°F)
Humidity
(Indoor)
1% to 99% ± 3.5% 1%
MeasurementRangeAccuracyResolution
Barometric300 to 1100 hPa (8.85 to 32.5 inHg) ± 5hPa 0.1hPa (0.01 inHg)
Temperature
(Indoor) 
-10°C to 60°C (-14°F to 140°F) ± 0.3°C (± 0.6°F) 0.1°C (0.1°F)
Humidity
(Indoor)
1% to 99% ± 3.5% 1%

Transmission between gateway and Wi-Fi router

  • Transmission distance in open field: 50 m (165 ft.)
    depending on router and environment
  • WLAN and Ethernet: 802.11 b/g/n (802.11n, Max 150 Mbps)
  • Updates on the Internet: Customize 1-5 minutes (recommend 1 minute)
  • Transmission distance in open field: 50 m (165 ft.)
    depending on router and environment
  • WLAN: 802.11 b/g/n (802.11n, Max 150 Mbps)
  • Updates on the Internet: Customize 1-5 minutes (recommend 1 minute)

Additional/optional sensor and console (sold separately)

Console
Sensor 
HP2550/2560GW1100/2000WN1900/1910HP3500WS2910WS2320WS6006
WS90 11
WS801111
WS691111111
WS681111
WH401111
WH32 Outdoor 1111
WH/WN 30/31/36/37 88888
WH518888
WH41/4344441+11
WH4511111
WH55 4444
WH571111
WN34 S/L 888
WN358888

Note: The "1+1" means 1*WH41 and 1*WH43